Diagnostic Electrophysiologic Testing - CAM 639HB

Description
General Information

  • It is an expectation that all patients receive care/services from a licensed clinician. All appropriate supporting documentation, including recent pertinent office visit notes, laboratory data, and results of any special testing must be provided. If applicable: All prior relevant imaging results and the reason that alternative imaging cannot be performed must be included in the documentation submitted.
  • Where a specific clinical indication is not directly addressed in this guideline, medical necessity determination will be made based on widely accepted standard of care criteria. These criteria are supported by evidence-based or peer-reviewed sources such as medical literature, societal guidelines and state/national recommendations.
  • The guideline criteria in the following sections were developed utilizing evidence-based and peer-reviewed resources from medical publications and societal organization guidelines as well as from widely accepted standard of care, best practice recommendations.

Purpose
For the performance of diagnostic electrophysiologic testing in patients with symptoms suspected to be caused by disturbances in the conduction or maintenance of cardiac rhythm.

Clinical Reasoning
All criteria are substantiated by the latest evidence-based medical literature. To enhance transparency and reference, Appropriate Use (AUC) scores, when available, are diligently listed alongside the criteria.

This guideline first defaults to AUC scores established by published, evidence-based guidance endorsed by professional medical organizations. In the absence of those scores, we adhere to a standardized practice of assigning an AUC score of 6. This score is determined by considering variables that ensure the delivery of patient-centered care in line with current guidelines, with a focus on achieving benefits that outweigh associated risks. This approach aims to maintain a robust foundation for decision-making and underscores our commitment to upholding the highest standards of care.(1–5)

INDICATIONS FOR DIAGNOSTIC ELECTROPHYSIOLOGIC TESTING (EPS) (6)
Sustained Narrow Complex Tachycardia (7)

  • To establish the mechanism of the rhythm when ablation is planned, including patients with preexcitation syndromes or Wolff-Parkinson-White (WPW), suspected AV nodal reentry, intraatrial reentry, atrioventricular reentry (over concealed accessory pathway), paroxysmal atrial flutter, and for mapping ectopic atrial tachycardia

Nonsustained Ventricular Tachycardia (NSVT), Frequent Ventricular Extrasystoles and Couplets (8,9)

  • Patients with other risk factors for future arrhythmic events, such as a low left ventricular ejection fraction (LVEF), positive signal-averaged electrocardiogram (ECG), and non- sustained ventricular tachycardia (VT) on ambulatory ECG recordings in whom EPS will be used for further risk assessment and for guiding therapy in patients with inducible sustained VT
  • Patients with highly symptomatic, monomorphic premature ventricular complexes (PVCs), couplets, and NSVT who are considered as potential candidates for catheter ablation
  • In patients with a prior myocardial infarction (MI), LVEF < 40%, and nonsustained VT, performance of an EPS with programmed ventricular stimulation is indicated for selecting suitable candidates for implantable cardioverter-defibrillator (ICD) implantation

Sustained Ventricular Tachycardia (8)
Structurally Normal Hearts

  • Sustained monomorphic ventricular tachycardia in patients with structurally normal hearts:
    • Before catheter ablation, an EPS should be offered to symptomatic patients with documented sustained monomorphic ventricular tachycardia

Structurally Abnormal Hearts

  • Sustained monomorphic ventricular tachycardia in patients with structurally abnormal hearts:
    • EPS should be performed preceding catheter ablation in patients with monomorphic sustained VT in candidates suitable for catheter ablation, typically in the same procedure
    • EPS is indicated in patients with wide QRS complex tachycardia in whom correct diagnosis is unclear after analysis of available ECG tracings, when knowledge of the correct diagnosis is required for patient care
    • EPS with standby catheter ablation should be considered in patients who develop VT following valvular surgery to identify and cure potential bundle branch re-entry VT
    • After catheter or surgical ablation of ventricular tachycardia, in patients with implantable defibrillators (ICD), programmed extra stimulation to assess the inducibility of clinically significant VT may be performed using the ICD when clinically indicated

After Surgical VT Ablation (9)

  • EPS may be performed in patients who have undergone surgical ablation of ventricular tachycardia, to determine inducibility of ventricular tachycardia and risk stratification for ICD implantation

Arrhythmogenic Right Ventricular Cardiomyopathy (ARVC) (8)

  • In patients with ARVC and documented sustained and hemodynamically well-tolerated ventricular tachycardia, EPS may be performed if ablation of the arrhythmia is planned. (Hemodynamically poorly tolerated VT in this entity is an indication for ICD, and EPS should not be done)
  • EPS may be performed in patients with ARVC and symptoms suggestive of malignant arrhythmia (palpitations and syncope) or NSVT when no documentation of sustained monomorphic VT exists. 

NOTE: EPS is not indicated in asymptomatic patients with AVRC without documented sustained VT, due to the poor predictive value of programmed extrastimulation in these patients.

NOTE: Diagnostic EPS has no place in the evaluation of patients with documented polymorphic ventricular tachycardia (PMVT). Similarly, EPS is not indicated in the evaluation of patients with Catecholaminergic Polymorphic Ventricular Tachycardia, although it may be considered for the ablation of the PVCs that initiate PMVT

Syncope 

  • EPS is indicated for the evaluation of syncope when noninvasive testing has been unrevealing; relevant clinical scenarios include (10):
    • Syncope with suspected sinus node dysfunction
    • Patients with syncope and left bundle branch block or bifascicular block (right bundle branch block and left anterior fascicular or left posterior fascicular block)
    • Patients with syncope and ischemic or other structural heart disease in which ventricular tachycardia is a potential cause for symptoms
    • Syncope in patients employed in high-risk occupations (airline pilots, bus drivers, police, firefighters, etc.)
    • Syncope immediately preceded by palpitations
    • Syncope or resuscitated sudden death in patients with preexcitation pattern on the ECG (WPW)
    • Unexplained syncope

Conduction Disturbances 
EPS is indicated for (11,12):

  • Symptomatic Type 2 AV block, to determine the site of block. (since permanent pacemaker implantation is indicated for block in or below the bundle of His)
  • Adult patients with myotonic muscular dystrophy, even in the absence of surface ECG abnormalities, to identify patients with a prolonged HV interval (>70 msec) in whom permanent pacemaker implantation should be considered
  • Risk stratification of asymptomatic preexcitation (WPW pattern on ECG) to determine the refractory period of the accessory pathway and/or the shortest pre-excited R-R interval in atrial fibrillation
  • Ventricular programmed extrastimulation may be performed in patients with cardiac sarcoidosis with a LVEF >35%, for risk stratification and consideration of ICD therapy

Coronary Artery Disease (8)

  • EPS is indicated in patients with CAD with remote MI with symptoms suggestive of ventricular tachyarrhythmias, including palpitations, presyncope, and syncope
  • EPS may be performed in patients with ischemic cardiomyopathy with LVEF 35-40% and non-sustained ventricular tachycardia (since inducible VT/VF is Class 1 indication for ICD)

Wide Complex Tachycardia (8)

  • EPS is indicated in evaluation of wide complex tachycardias, including left bundle branch block, to establish the mechanism of the rhythm disturbance and to aid in determining correct management (i.e., to exclude pre-excited tachycardia in WPW or Mahaim-related tachycardia mimicking ventricular tachycardia), and to determine eligibility for catheter ablation or ICD implantation

Congenital Heart Disease(11)

  • EPS is indicated in adults with congenital heart disease and life-threatening arrhythmias or resuscitated sudden cardiac death, when the cause for the event is unknown or there is potential for therapeutic intervention (ablation) at the time of the electrophysiological procedure
  • EPS may be performed in patients with congenital heart disease with unexplained syncope with impaired ventricular function (LVEF <50%). In these patients, in the absence of a defined and reversible cause, ICD implantation is considered reasonable.
  • EPS may be used for risk stratification in adults with Tetralogy of Fallot (TOF) who have additional risk factors for sudden cardiac death, defined as left ventricular systolic or diastolic dysfunction, nonsustained VT, QRS duration of ≥180 msec, and extensive right ventricular scarring.
  • EPS is indicated for diagnostic evaluation of adults with Ebstein anomaly and asymptomatic ventricular preexcitation or symptomatic arrhythmia (13)
  • EPS (and catheter ablation, if needed) is reasonable for adults with Ebstein anomaly before surgical intervention on the tricuspid valve (13)

NOTE: EPS/programmed extrastimulation is not indicated in the evaluation of Long QT Syndromes, Short QT Syndromes, or Early Repolarization. Studies of EPS in Brugada Syndrome have demonstrated poor correlation between inducibility and prognosis, and EPS is not recommended

NOTE: In survivors of cardiac arrest not due to a reversible cause, ICD implantation without prior performance of an EPS is appropriate, with rare exceptions.

BACKGROUND
Invasive Cardiac Electrophysiology Studies (EPS) involve the use of multielectrode catheters introduced into the cardiac chambers, and typically positioned in the right atrium, right ventricle, region of the A-V Node and the Bundle of His, and frequently the coronary sinus. 

Several vascular access sites are typically needed, and may include the femoral vein(s), jugular vein(s), subclavian vein(s) and the brachial vein(s). Under certain circumstances, access to the left heart may require either transseptal puncture or a retrograde approach via the femoral artery across the aortic valve. In these cases, systemic anticoagulation is mandated. 

After initial recordings of baseline electrograms from the catheters, programmed extrastimulation of the various cardiac chambers may be undertaken to study conduction characteristics, physiology of the conduction system, and in an attempt inducibility of clinically relevant tachydysrhythmias. Provocation with drugs that affect electrical conduction, including atropine, isoproterenol, and adenosine, is commonly utilized to enhance the inducibility of abnormal heart rhythms. 

EPS is typically performed in conjunction with catheter ablation of previously documented tachydysrhythmias, to confirm the mechanism of the rhythm disturbance and to facilitate its induction, which is required to identify the critical site(s) for ablation.

SUMMARY OF EVIDENCE
2017 AHA/ACC/HRS Guideline for Management of Patients with Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death (8)
Study Design: This document is a clinical practice guideline developed by the American College of Cardiology, American Heart Association, and Heart Rhythm Society. It is based on systematic methods to evaluate and classify evidence, including literature searches, randomized controlled trials, registries, nonrandomized comparative and descriptive studies, case series, cohort studies, systematic reviews, and expert opinion.

Target Population: The guideline is intended for adults who have ventricular arrhythmias (VA) or are at risk for sudden cardiac death (SCD), including those with diseases and syndromes associated with a risk of SCD from VA.

Key Factors: The guideline covers various aspects such as epidemiology, mechanisms of VA, general evaluation of patients, therapies for treatment or prevention of VA, acute management of specific VA, ongoing management of VA and SCD risk related to specific disease states, and special considerations for catheter ablation.

PACES/HRS Expert Consensus Statement on the Recognition and Management of Arrhythmias in Adult Congenital Heart Disease (11)
Study Design: This document is an expert consensus statement developed by the Pediatric and Congenital Electrophysiology Society (PACES) and the Heart Rhythm Society (HRS), endorsed by several other organizations. It is based on formal literature reviews, expert opinion, and evidence-based recommendations.

Target Population: The statement focuses on adults with congenital heart disease (CHD) and arrhythmias, including those with various types of CHD such as atrial septal defects, Ebstein anomaly, tetralogy of Fallot, and Fontan procedure.

Key Factors: The document addresses the recognition and management of arrhythmias in adults with CHD, including epidemiology, delivery of care, evaluation and diagnosis, medical therapy, catheter ablation, bradyarrhythmias and pacemakers, sudden cardiac death and ICDs, cardiac resynchronization therapy, surgical options, and recommendations for electrophysiologic study prior to adult CHD surgery.

Recommendations for the use of electrophysiological study: Update 2018 (6)
Study Design: This document is a review article that provides updated recommendations for the use of electrophysiological studies (EPS) in clinical practice. It is based on a comprehensive review of relevant articles, clinical practice guidelines, and position statements from various organizations.

Target Population: The recommendations are intended for patients with different types of cardiac pathologies, including sinus node dysfunction, atrioventricular block, bundle branch block, narrow and wide QRS complex tachycardias, inherited primary arrhythmia syndromes, progressive cardiac conduction disease, early repolarization syndrome, hypertrophic cardiomyopathy, dilated cardiomyopathy, arrhythmogenic right ventricular cardiomyopathy, left ventricular noncompaction, muscular dystrophies, ischemic heart disease, infiltrative diseases, congenital heart disease, unexplained syncope, survivors of cardiac arrest, undocumented palpitations, and candidates for or carriers of cardiac implantable electronic devices.

Key Factors: The document discusses the role of EPS in diagnosing and managing various cardiac conditions, guiding catheter ablation procedures, and establishing indications for cardiac device implantation. It provides detailed recommendations for each cardiac disease/group of diseases, including the rationale, evidence, and specific indications for EPS.

ANALYSIS OF EVIDENCE
Shared Findings (6,8,11):

  • Importance of EPS: All three documents emphasize the importance of EPS in diagnosing and managing cardiac arrhythmias and conduction disorders. EPS is considered a valuable tool for evaluating patients with various cardiac conditions and guiding therapeutic interventions.
  • Role in Risk Stratification: EPS is highlighted as a key method for risk stratification in patients with ventricular arrhythmias and sudden cardiac death risk. It helps identify patients who may benefit from implantable cardioverter-defibrillators (ICDs) and other preventive measures.
  • Guidance for Catheter Ablation: EPS is recognized as essential for guiding catheter ablation procedures, particularly in patients with complex arrhythmias and structural heart disease.

Conclusion (6,8,11):
In summary, while all three documents highlight the importance of EPS in diagnosing and managing cardiac arrhythmias, they differ in their target populations, specific recommendations, and focus areas. Al-Khatib et al 2018 and Khairy et al 2014 provide general guidelines and consensus statements, whereas Muresan et al 2019 offers detailed recommendations for a wide range of cardiac conditions.

Definitions
Sustained Tachycardia: tachycardia lasting 20 seconds or longer, or requiring cardioversion because of hemodynamic collapse

AUC Score
A reasonable diagnostic or therapeutic procedure can be defined as that for which the expected clinical benefits outweigh the associated risks, enhancing patient care and health outcomes in a cost-effective manner.(4)

  • Appropriate Care- Median Score 7-9
  • May be Appropriate Care- Median Score 4-6 
  • Rarely Appropriate Care- Median Score 1-3

Acronyms/Abbreviations

  • ARVC: Arrhythmogenic right ventricular cardiomyopathy
  • A-V Node: Atrioventricular node
  • AUC: Appropriate use criteria
  • CAD: Coronary Artery Disease
  • ECG: Electrocardiogram
  • EPS: Electrophysiology studies
  • ICD: Implantable Cardioverter-Defibrillator
  • LVEF: Left ventricular ejection fraction
  • MI: Myocardial Infarction
  • NSVT: Non-sustained ventricular tachycardia
  • PMVT: Polymorphic ventricular tachycardia
  • PVC: Premature ventricular complexes
  • QRSd: Duration of the QRS complex
  • TOF: Tetralogy of Fallot
  • VT: Ventricular tachycardia
  • VF: Ventricular fibrillation
  • WPW: Wolff-Parkinson-White

References

  1. Bonow RO, Douglas PS, Buxton AE, et al. ACCF/AHA Methodology for the Development of Quality Measures for Cardiovascular Technology. J Am Coll Cardiol. 2011;58(14):1517-1538. doi:10.1016/j.jacc.2011.07.007
  2. Fitch Kathryn, Bernstein SJ, Aguilar MD, et al. The RAND/UCLA Appropriateness Method User’s Manual. RAND.; 2001. Accessed October 8, 2024. https://www.rand.org/pubs/monograph_reports/MR1269.html
  3. Hendel RC, Patel MR, Allen JM, et al. Appropriate Use of Cardiovascular Technology: 2013 ACCF appropriate use criteria methodology update. J Am Coll Cardiol. 2013;61(12):1305-1317. doi:10.1016/j.jacc.2013.01.025
  4. Hendel RC, Lindsay BD, Allen JM, et al. ACC Appropriate Use Criteria Methodology: 2018 Update. J Am Coll Cardiol. 2018;71(8):935-948. doi:10.1016/j.jacc.2018.01.007
  5. Patel MR, Spertus JA, Brindis RG, et al. ACCF Proposed Method for Evaluating the Appropriateness of Cardiovascular Imaging. J Am Coll Cardiol. 2005;46(8):1606-1613. doi:10.1016/j.jacc.2005.08.030
  6. Muresan L, Cismaru G, Martins RP, et al. Recommendations for the use of electrophysiological study: Update 2018. Hellenic Journal of Cardiology. 2019;60(2):82-100. doi:10.1016/j.hjc.2018.09.002
  7. Page RL, Joglar JA, Caldwell MA, et al. 2015 ACC/AHA/HRS Guideline for the Management of Adult Patients With Supraventricular Tachycardia: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol. 2016;67(13):e27-e115. doi:10.1016/j.jacc.2015.08.856
  8. Al-Khatib SM, Stevenson WG, Ackerman MJ, et al. 2017 AHA/ACC/HRS Guideline for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death. J Am Coll Cardiol. 2018;72(14):e91-e220. doi:10.1016/j.jacc.2017.10.054
  9. Muser D, Hayashi T, Castro SA, et al. Noninvasive Programmed Ventricular Stimulation-Guided Management Following Ventricular Tachycardia Ablation. JACC Clin Electrophysiol. 2019;5(6):719-727. doi:10.1016/j.jacep.2019.03.007
  10. Brignole M, Moya A, de Lange FJ, et al. 2018 ESC Guidelines for the diagnosis and management of syncope. Eur Heart J. 2018;39(21):1883-1948. doi:10.1093/eurheartj/ehy037
  11. Khairy P, Van Hare GF, Balaji S, et al. PACES/HRS Expert Consensus Statement on the Recognition and Management of Arrhythmias in Adult Congenital Heart Disease. Heart Rhythm. 2014;11(10):e102-e165. doi:10.1016/j.hrthm.2014.05.009
  12. Kusumoto FM, Schoenfeld MH, Barrett C, et al. 2018 ACC/AHA/HRS Guideline on the Evaluation and Management of Patients With Bradycardia and Cardiac Conduction Delay: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol. 2019;74(7):e51-e156. doi:10.1016/j.jacc.2018.10.044
  13. Gurvitz M, Krieger E V., Fuller S, et al. 2025 ACC/AHA/HRS/ISACHD/SCAI Guideline for the Management of Adults With Congenital Heart Disease. JACC. Published online December 2025. doi:10.1016/j.jacc.2025.09.006

Coding Section

Code

Description

93619

Comprehensive electrophysiologic evaluation with right atrial pacing and recording, right ventricular pacing and recording, His bundle recording, including insertion and repositioning of multiple electrode catheters, without induction or attempted induction of arrhythmia        

93620

Comprehensive electrophysiologic evaluation including insertion and repositioning of multiple electrode catheters with induction or attempted induction of arrhythmia; with right atrial pacing and recording, right ventricular pacing and recording, His bundle recording

93642

Electrophysiologic evaluation of single or dual chamber transvenous pacing cardioverter-defibrillator (includes defibrillation threshold evaluation, induction of arrhythmia, evaluation of sensing and pacing for arrhythmia termination, and programming or reprogramming of sensing or therapeutic parameters)

+93609

Intraventricular and/or intra-atrial mapping of tachycardia site(s) with catheter manipulation to record from multiple sites to identify origin of tachycardia (List separately in addition to code for primary procedure)

+93613

Intracardiac electrophysiologic 3-dimensional mapping (List separately in addition to code for primary procedure)

+93621

Comprehensive electrophysiologic evaluation including insertion and repositioning of multiple electrode catheters with induction or attempted induction of arrhythmia; with left atrial pacing and recording from coronary sinus or left atrium (List separately in addition to code for primary procedure)

+93622

Comprehensive electrophysiologic evaluation including insertion and repositioning of multiple electrode catheters with induction or attempted induction of arrhythmia; with left ventricular pacing and recording (List separately in addition to code for primary procedure)

+93655

Intracardiac catheter ablation of a discrete mechanism of arrhythmia which is distinct from the primary ablated mechanism, including repeat diagnostic maneuvers, to treat a spontaneous or induced arrhythmia (List separately in addition to code for primary procedure)

Procedure and diagnosis codes on Medical Policy documents are included only as a general reference tool for each Policy. They may not be all-inclusive.

This medical policy was developed through consideration of peer-reviewed medical literature generally recognized by the relevant medical community, U.S. FDA approval status, nationally accepted standards of medical practice and accepted standards of medical practice in this community, and other nonaffiliated technology evaluation centers, reference to federal regulations, other plan medical policies and accredited national guidelines.

"Current Procedural Terminology © American Medical Association. All Rights Reserved" 

History From 2026 Forward

11/01/2026 New Policy