Amublatory Rhythm Monitoring - CAM 638HB
Description
General Information
- It is an expectation that all patients receive care/services from a licensed clinician. All appropriate supporting documentation, including recent pertinent office visit notes, laboratory data, and results of any special testing must be provided. If applicable: All prior relevant imaging results and the reason that alternative imaging cannot be performed must be included in the documentation submitted.
- Where a specific clinical indication is not directly addressed in this guideline, medical necessity determination will be made based on widely accepted standard of care criteria. These criteria are supported by evidence-based or peer-reviewed sources such as medical literature, societal guidelines and state/national recommendations.
- The guideline criteria in the following sections were developed utilizing evidence-based and peer-reviewed resources from medical publications and societal organization guidelines as well as from widely accepted standard of care, best practice recommendations
Purpose
To identify appropriate use for ambulatory rhythm monitoring.
Clinical Reasoning
All criteria are substantiated by the latest evidence-based medical literature. To enhance transparency and reference, Appropriate Use (AUC) scores, when available, are diligently listed alongside the criteria.
This guideline first defaults to AUC scores established by published, evidence-based guidance endorsed by professional medical organizations. In the absence of those scores, we adhere to a standardized practice of assigning an AUC score of 6. This score is determined by considering variables that ensure the delivery of patient-centered care in line with current guidelines, with a focus on achieving benefits that outweigh associated risks. This approach aims to maintain a robust foundation for decision-making and underscores our commitment to upholding the highest standards of care.(1–5)
INDICATIONS FOR AMBULATORY RHYTHM MONITORING(6)
- Palpitations are the most common indication for ambulatory heart rhythm monitoring
- Evaluation of arrhythmia drug therapy change including dosage alterations
- Patients with suspected epilepsy in whom treatment has been ineffective(7)
- Patients with unexplained falls suspected to have an arrhythmic origin (7)
- Suspected pacemaker malfunction, based on history and physical exam
- Syncope:
- Symptom/rhythm correlation remains the cornerstone of the diagnostic efforts in syncope to confirm the involvement of the cardiac electrical system in the origin of syncope. The choice of monitoring modality depends on the frequency of the events
- Symptoms that may be due to cardiac arrhythmias and for which ambulatory monitoring is appropriate, include:
- Shortness of breath
- Transient chest pain
- Palpitations (when physical examination and/or standard ECG have not satisfactorily explained the patient's complaints)
- Transient episode of cerebral ischemia, documented cerebrovascular accident (CVA), or recent evidence of cryptogenic stroke, to evaluate for a causation rhythm disturbance (e.g., atrial fibrillation or flutter)(8)
- Patient with a recent acute coronary syndrome:
- ST-elevation myocardial infarction (STEMI) and non-STEMI when the ejection fraction is borderline (35-40%), or when frequent ventricular ectopy was noted during hospitalization
- Cardiomyopathy:
- Hypertrophic cardiomyopathy
- Arrhythmogenic right ventricular cardiomyopathy
- Dilated or restrictive cardiomyopathy
- Ischemic cardiomyopathy
- For patients found to have a significant cardiac arrhythmia or conduction disorder (see list below) in whom cardiac monitoring is planned for the evaluation and management of the patient:
- Symptomatic Ectopy
- Premature ventricular contraction (PVCs) (9)
- Premature atrial contraction (PACs)
- Supraventricular tachycardia (SVT) (sustained or non-sustained)(9)
- Ventricular tachycardia (VT) (sustained or non-sustained)(9)
- Ventricular fibrillation/flutter(9)
- Unexplained or symptomatic bradycardia
- Suspected sinus node dysfunction
- Paroxysmal atrial fibrillation/flutter(8)
- Torsade de pointes
- Wandering atrial pacemaker
- Cardiac arrest,(9) when electrophysiology testing or implantable cardioverter defibrillator (ICD) implantation are not planned
- Symptomatic Ectopy
- Post cardiovascular surgery:
- Indicated for outpatient arrhythmia monitoring of rhythm disturbances noted during hospitalization
- Inherited channelopathies:
- First degree relatives of patients with idiopathic ventricular fibrillation
- Long and short QT syndromes
- Brugada syndrome
- Early repolarization with high-risk features (see background)
- Catecholaminergic polymorphic ventricular tachycardia
- Conduction disorders:
- New or Intermittent Left Bundle Branch Block (LBBB)
- High-Degree Atrioventricular (AV) block
- Second Degree AV Block
- Transient Complete Heart Block
- Preexcitation on ECG (Wolf-Parkinson-White), symptomatic or asymptomatic
- Congenital Heart Disease (CHD):
- Congenital aortic stenosis
- Pediatrics patients with repaired CHD or with significant residual hemodynamic abnormalities
- In adults with dextro-Transposition of the Great Arteries (d-TGA) and atrial switch with new or progressive symptoms of heart failure(10)
- In adults with congenitally corrected transposition of the great arteries (CCTGA) without symptoms to screen for high-grade atrioventricular block(10)
- Autonomic Function Analysis:
- Heart rate variability may be performed using Holter monitoring. It provides sudden cardiac death risk stratification data post-MI and in patients with heart failure. It has proved useful in patients with resynchronization devices (CRT) to evaluate optimal timing of biventricular pacing.
SELECTION OF DEVICES FOR AMBULATORY RHYTHM MONITORING(6,11)
The choice of a specific cardiac monitor should be determined on the basis of the frequency and nature of symptoms/events(11)
Holter Monitor
Indicated for:
- Screening for unrecognized rhythm disturbances in patients with symptoms that may be related to transient arrhythmias
- Determination of the frequency of known rhythm disturbances (PVCs, runs of NSVT, etc.)
- Identification of asymptomatic atrial fibrillation in patients with TIA or CVA
- Evaluation of unexplained syncope
- Evaluation of palpitations or subjective rhythm complaints that occur frequently enough to be detected within a short period (24-72 hours) of monitoring
- Holter monitoring (48-72 hours) is the modality of first choice in screening patients to detect the frequency of asymptomatic or minimally symptomatic dysrhythmias
Holter monitoring is typically used for short term (1-2 days), and rarely longer term (up to 2 weeks) study duration.(12)
Event Recorder
Indicated for:
- Evaluation of frequent, but typically not daily, symptomatic episodes potentially related to tachycardia, bradycardia, or conduction disorders. Although auto-activation features exist, these devices are most useful when the patient can identify the symptom and activate the recording feature.
Event Recorders are usually worn for 2-4 weeks.
Wireless Patch Monitoring Systems
Indicated for:
- An alternative to external loop recorder or Holter monitor for both symptomatic and asymptomatic dysrhythmias, likely to occur within 2-4 weeks
- Since it is leadless, can be accurately self-applied, and is largely water resistant, it may be more comfortable and less cumbersome than an external loop recorder, potentially improving compliance
- Unlike Holter monitors and other external monitors, it offers only 1-lead recording
Mobile Cardiac Outpatient Telemetry
Indicated for:
- Evaluation of spontaneous symptoms, potentially related to tachycardia, bradycardia or conduction disorder, that are too brief, too subtle, or too infrequent to be readily documented with patient-activated monitors or Holter monitors
- Useful to assess the presence and frequency of asymptomatic but potentially significant dysrhythmias, including, but not limited to atrial fibrillation, ventricular ectopy, and bradycardias
- May be utilized when other forms of monitoring do not identify the source of symptoms (e.g., Holter Monitoring)
Implantable Loop Recorder (ILR)
Indicated for:
- Monitoring electrical activity of the heart over an extended period, for up to 3 years, to capture a spontaneous event when symptoms occur less than monthly or a few times per year
- Recurrent, infrequent, unexplained symptoms, potentially related to tachycardia, bradycardia or conduction disorder after a nondiagnostic initial workup (including Holter, Patch Monitor, or Mobile Cardiac Outpatient Telemetry), with or without structural heart disease
- ILR may be implanted after cryptogenic stroke to rule out unrecognized atrial fibrillation if Holter monitor, patch recorder or MCOT has failed to identify a causative rhythm disturbance. (A short-term monitoring system must be utilized before the ILR may be used)
INDICATIONS FOR REMOVAL OF LOOP RECORDER SYSTEMS
- Implantable loop recorder (ILR) may be removed for:
- End of battery life
- Pain, discomfort, infection at ILR site, or patient desires the device to be removed(13)
LIMITATIONS
- Loop recorder implantation in presence of another electrical device (AICD/PPM/CRT device etc.) is not indicated
- Loop recorder implantation post atrial fibrillation ablation is not routinely indicated and will be addressed on a case-by-case basis
SUMMARY OF EVIDENCE
ESC Working Group on e-Cardiology Position Paper: accuracy and reliability of electrocardiogram monitoring in the detection of atrial fibrillation in cryptogenic stroke patients(8)
Study Design: This position paper by the European Society of Cardiology Working Group on e-Cardiology discusses the accuracy and reliability of electrocardiogram (ECG) monitoring in detecting atrial fibrillation (AF) in cryptogenic stroke patients.
Target Population: Cryptogenic stroke patients, particularly those with subclinical AF.
Key Factors:
- The paper presents the definition, epidemiology, and clinical impact of cryptogenic ischemic stroke and its association with occult AF.
- It discusses classification methods for ischemic stroke and patient selection criteria for long-term ECG monitoring.
- The paper evaluates non-invasive and invasive ECG monitoring tools, highlighting the advantages of implantable cardiac monitors.
- Institutional and organizational issues such as reimbursement, patient management, data ownership, and handling are briefly touched upon.
2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry(6)
Study Design: This expert consensus statement by the International Society for Holter and Noninvasive Electrocardiology (ISHNE) and the Heart Rhythm Society (HRS) reviews ambulatory ECG (AECG) and external cardiac monitoring/telemetry.
Target Population: Patients with intermittent cardiac arrhythmias, those undergoing arrhythmic drug therapy, and those needing prognosis assessment in specific clinical contexts.
Key Factors:
- The statement reviews how contemporary AECG devices acquire and process ECG signals and their clinical applications.
- It discusses the appropriate utilization of these devices in managing cardiovascular disease and promoting standards for improving AECG accuracy.
- The document provides background and framework for applying AECG techniques in clinical practice and research.
- It includes detailed sections on modalities, technology, equipment, signal acquisition, processing, and interpretation.
2022 ESC Guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death(9)
Study Design: These guidelines by the European Society of Cardiology (ESC) focus on the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death.
Target Population: Patients with ventricular arrhythmias and those at risk of sudden cardiac death.
Key Factors:
- The guidelines cover definitions, epidemiology, diagnostic tools, and therapeutic strategies for ventricular arrhythmias and sudden cardiac death.
- They provide recommendations for public basic life support, access to automated external defibrillators, and genetic testing.
- The document includes algorithms for evaluating patients with newly documented ventricular arrhythmias and managing specific structural heart diseases.
- It discusses the role of implantable cardioverter defibrillators, catheter ablation, and pharmacotherapy in long-term management.
ANALYSIS OF EVIDENCE
Shared Findings(6,8,9):
- Importance of Long-term Monitoring: All three articles emphasize the significance of long-term ECG monitoring for detecting arrhythmias, particularly atrial fibrillation and ventricular arrhythmias. Long-term monitoring increases the likelihood of detecting infrequent arrhythmias that may not be captured during short-term recordings.
- Technological Advancements: The articles highlight the advancements in AECG technology, including the integration of multiple biological signal sensors and the use of wireless data transmission. These advancements improve the diagnostic yield and ease of use of AECG devices.
- Clinical Applications: The articles discuss the clinical applications of AECG devices in managing cardiovascular disease, including the detection of arrhythmias, assessment of prognosis, and guiding therapeutic interventions.
Conclusion(6,8,9):
In summary, while all three articles emphasize the importance of long-term ECG monitoring and technological advancements in AECG devices, they differ in their focus on specific conditions, evaluation of monitoring tools, and recommendations for public health. Dilaveris et al 2022 focuses on atrial fibrillation detection in cryptogenic stroke patients, Steinberg et al 2017 provides a comprehensive overview of AECG technology, and Zeppenfeld et al 2022 offers detailed guidelines for managing ventricular arrhythmias and preventing sudden cardiac death.
Definitions
Ambulatory ECG Monitoring
Ambulatory ECG Monitoring is the continuous monitoring on an outpatient basis of the electrical activity of the heart while the patient undergoes their usual activities. The duration of the monitoring period should be long enough to capture heart rhythm abnormalities based on the patient’s description of the frequency of their symptoms.
Holter Monitor
Holter monitors are continuous single and multi-lead external recorders wire-lead devices. These utilize standard wet gel electrodes worn continuously to record ECG data. Recordings may be in 2-channel (two independent bipolar leads), 3-channel, 12-channel, or EASI lead formats. They are traditionally used for 24–48 hr., although some models permit recording periods up to 30 consecutive days. They are most effective when patients maintain a diary of activities and symptoms, and mark occurrence of symptoms by pressing a button on the device. Data are analyzed post recording on a dedicated workstation.
Event Recorders
External event recorders are activated and record only at the time of detection (either automatically by the device or manually activated by the patient). They use gel electrodes connected via wires to the recording device. Event recorders are worn continuously, for varying periods of time, typically 2-weeks to one-month. They record the rhythm in a continuously renewed loop, but when activated, will store the data from the rhythm in memory. This information can be downloaded to the physician’s office at the convenience of the patient post-event. Newer models can transmit triggered data automatically over a cellular network to a remote monitoring system.
Simpler non-looping post event recorders are not worn continuously. Rather, these portable devices with built-in electrodes are applied directly on the chest (or held by both hands) to record a very brief duration single-lead ECG signal during symptoms. They require that the patient be aware of the rhythm disturbance, that it lasts long enough to mobilize the device, and that the patient is able to cooperate with its use.
Patch ECG Monitors
Continuous, usually single-lead external recorders with wireless transmission (patch ECG monitors) are wearable adhesive patches with embedded electrodes that store rhythm data collected either automatically or when activated by the patient. These on-skin wearable devices eliminate the need for patient cable wires and discrete electrodes; they are comfortable to wear and water-resistant, and do not interfere with patients' daily routines. Patients can press a button to mark symptomatic episodes. Up to 7–14 days of ambulatory monitoring yields a high rate of arrhythmia identification.
MCOT
Mobile cardiac outpatient telemetry (MCOT) devices are worn continuously and have been produced with varying monitor configurations. They are capable of real-time streaming, transmitting a loop, or a single event electrogram directly to the reading center via a wireless link. Newest iterations can connect via Wi-Fi to transmit data.
The MCOT data are processed in a reading center on the back end of the monitoring system. The arrhythmic events are analyzed by trained technicians, and alarms are distributed to patient caregivers. Many MCOT devices are also equipped with real-time signal processing algorithms providing detection of cardiac arrhythmias.
ILR
The implantable loop recorder (ILR) is a patient-activated monitoring system that records ECG tracings and is indicated for patients who experience transient symptoms that may suggest a cardiac arrhythmia. The device is a programmable cardiac event recorder with looping memory and is implanted subcutaneously usually in a left pectoral or mammary location with a battery life of 15-36 months. The electrodes that sense the heart's activity are on the surface of the device, so no trans venous leads are required. This device allows continuously looping rhythm monitoring. Data are stored either when manually activated by a patient or automatically when high or low-rate parameters are met.
Early Repolarization Syndrome (ERS) High Risk Features(9)
- Family history of unexplained SD < 40 years
- Family history of ERS
- High risk Early Repolarization Pattern (ERP)
- J-waves > 2 mm
- Dynamic changes in J point and flat or downsloping ST morphology
AUC Score
A reasonable diagnostic or therapeutic procedure can be defined as that for which the expected clinical benefits outweigh the associated risks, enhancing patient care and health outcomes in a cost-effective manner.(4)
- Appropriate Care- Median Score 7-9
- May be Appropriate Care- Median Score 4-6
- Rarely Appropriate Care- Median Score 1-3
Acronyms/Abbreviations
- AICD: automatic implanted cardioverter defibrillator
- AUC: appropriate use score
- AV: atrioventricular
- BBB: bundle branch block
- BrS: Brugada Syndrome
- CHD: congenital heart disease
- CRT: cardiac resynchronization therapy
- CVA: cerebrovascular accident
- d-TGA: dextro-Transposition of the Great Arteries
- EASI: A modified set-up that can derive 12-lead ECG signals from only 5 ECG channels
- ECG: electrocardiogram
- ERP: early repolarization pattern
- ERS: early repolarization syndrome
- ICD: implantable cardioverter defibrillator
- ILR: implantable loop recorder
- LBBB: left bundle branch block
- MCOT: mobile cardiac outpatient telemetry
- MCT: mobile cardiac telemetry
- MI: myocardial infarction
- mm: millimeter
- PAC: premature atria complexes
- PPM: permanent pacemaker
- PVC: premature ventricular complexes
- QT: QT interval is section on ECG
- s: seconds
- SCD: sudden cardiac death
- SD: sudden death
- ST: ST segment on ECG
- STEMI: ST elevation myocardial infarction
- SQTS: Short QT Syndrome
- SVT: supraventricular tachycardia
- VT: ventricular tachycardia
- WPW: Wolfe-Parkinson-White
References
- Bonow RO, Douglas PS, Buxton AE, et al. ACCF/AHA Methodology for the Development of Quality Measures for Cardiovascular Technology. J Am Coll Cardiol. 2011;58(14):1517-1538. doi:10.1016/j.jacc.2011.07.007
- Fitch Kathryn, Bernstein SJ, Aguilar MD, et al. The RAND/UCLA Appropriateness Method User’s Manual. RAND.; 2001. Accessed October 8, 2024. https://www.rand.org/pubs/monograph_reports/MR1269.html
- Hendel RC, Patel MR, Allen JM, et al. Appropriate Use of Cardiovascular Technology: 2013 ACCF appropriate use criteria methodology update. J Am Coll Cardiol. 2013;61(12):1305-1317. doi:10.1016/j.jacc.2013.01.025
- Hendel RC, Lindsay BD, Allen JM, et al. ACC Appropriate Use Criteria Methodology: 2018 Update. J Am Coll Cardiol. 2018;71(8):935-948. doi:10.1016/j.jacc.2018.01.007
- Patel MR, Spertus JA, Brindis RG, et al. ACCF Proposed Method for Evaluating the Appropriateness of Cardiovascular Imaging. J Am Coll Cardiol. 2005;46(8):1606-1613. doi:10.1016/j.jacc.2005.08.030
- Steinberg JS, Varma N, Cygankiewicz I, et al. 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry. Heart Rhythm. 2017;14(7):e55-e96. doi:10.1016/j.hrthm.2017.03.038
- Brignole M, Moya A, de Lange FJ, et al. 2018 ESC Guidelines for the diagnosis and management of syncope. Eur Heart J. 2018;39(21):1883-1948. doi:10.1093/eurheartj/ehy037
- Dilaveris PE, Antoniou CK, Caiani EG, et al. ESC Working Group on e-Cardiology Position Paper: accuracy and reliability of electrocardiogram monitoring in the detection of atrial fibrillation in cryptogenic stroke patients. European Heart Journal - Digital Health. 2022;3(3):341-358. doi:10.1093/ehjdh/ztac026
- Zeppenfeld K, Tfelt-Hansen J, de Riva M, et al. 2022 ESC Guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death. Eur Heart J. 2022;43(40):3997-4126. doi:10.1093/eurheartj/ehac262
- Gurvitz M, Krieger E V., Fuller S, et al. 2025 ACC/AHA/HRS/ISACHD/SCAI Guideline for the Management of Adults With Congenital Heart Disease. JACC. Published online December 2025. doi:10.1016/j.jacc.2025.09.006
- Shen WK, Sheldon RS, Benditt DG, et al. 2017 ACC/AHA/HRS Guideline for the Evaluation and Management of Patients With Syncope. J Am Coll Cardiol. 2017;70(5):e39-e110. doi:10.1016/j.jacc.2017.03.003
- Hassani S, El Husseini N, Feng W, Lloyd M, Quyyumi A. A Patient‐Centered Approach to Cardiac Monitoring After Cryptogenic Stroke: A Review. Stroke: Vascular and Interventional Neurology. 2024;4(2). doi:10.1161/SVIN.123.001126
- Vilcant V, Kousa O, Hai O. Implantable Loop Recorder. StatPearls. Published online July 24, 2023. https://www.ncbi.nlm.nih.gov/books/NBK470398/
Coding Section
| Code | Number | Description |
| CPT |
33285 |
Insertion, subcutaneous cardiac rhythm monitor, including programming |
| 33286 |
Removal, subcutaneous cardiac rhythm monitor |
|
| 93224 |
External electrocardiographic recording up to 48 hours by continuous rhythm recording and storage; includes recording, scanning analysis with report, review and interpretation by a physician or other qualified health care professional |
|
| 93225 |
External electrocardiographic recording up to 48 hours by continuous rhythm recording and storage; recording (includes connection, recording, and disconnection) |
|
| 93226 |
External electrocardiographic recording up to 48 hours by continuous rhythm recording and storage; scanning analysis with report |
|
| 93227 |
External electrocardiographic recording up to 48 hours by continuous rhythm recording and storage; review and interpretation by a physician or other qualified health care professional |
|
| 93228 |
External mobile cardiovascular telemetry with electrocardiographic recording, concurrent computerized real time data analysis and greater than 24 hours of accessible ECG data storage (retrievable with query) with ECG triggered and patient selected events transmitted to a remote attended surveillance center for up to 30 days; review and interpretation with report by a physician or other qualified health care professional |
|
| 93229 |
External mobile cardiovascular telemetry with electrocardiographic recording, concurrent computerized real time data analysis and greater than 24 hours of accessible ECG data storage (retrievable with query) with ECG triggered and patient selected events transmitted to a remote attended surveillance center for up to 30 days; technical support for connection and patient instructions for use, attended surveillance, analysis and transmission of daily and emergent data reports as prescribed by a physician or other qualified health care professional |
|
| 93241 |
External electrocardiographic recording for more than 48 hours up to 7 days by continuous rhythm recording and storage; includes recording, scanning analysis with report, review and interpretation |
|
| 93242 |
External electrocardiographic recording for more than 48 hours up to 7 days by continuous rhythm recording and storage; recording (includes connection and initial recording) |
|
| 93243 |
External electrocardiographic recording for more than 48 hours up to 7 days by continuous rhythm recording and storage; scanning analysis with report |
|
| 93244 |
External electrocardiographic recording for more than 48 hours up to 7 days by continuous rhythm recording and storage; review and interpretation |
|
| 93245 |
External electrocardiographic recording for more than 7 days up to 15 days by continuous rhythm recording and storage; includes recording, scanning analysis with report, review and interpretation |
|
| 93246 |
External electrocardiographic recording for more than 7 days up to 15 days by continuous rhythm recording and storage; recording (includes connection and initial recording) |
|
| 93247 |
External electrocardiographic recording for more than 7 days up to 15 days by continuous rhythm recording and storage; scanning analysis with report |
|
| 93248 |
External electrocardiographic recording for more than 7 days up to 15 days by continuous rhythm recording and storage; review and interpretation |
|
| 93268 |
External patient and, when performed, auto activated electrocardiographic rhythm derived event recording with symptom-related memory loop with remote download capability up to 30 days, 24-hour attended monitoring; includes transmission, review and interpretation by a physician or other qualified health care professional |
|
| 93270 |
External patient and, when performed, auto activated electrocardiographic rhythm derived event recording with symptom-related memory loop with remote download capability up to 30 days, 24-hour attended monitoring; recording (includes connection, recording, and disconnection) |
|
| 93271 |
External patient and, when performed, auto activated electrocardiographic rhythm derived event recording with symptom-related memory loop with remote download capability up to 30 days, 24-hour attended monitoring; transmission and analysis |
|
| 93272 |
External patient and, when performed, auto activated electrocardiographic rhythm derived event recording with symptom-related memory loop with remote download capability up to 30 days, 24-hour attended monitoring; review and interpretation by a physician or other qualified health care professional |
Procedure and diagnosis codes on Medical Policy documents are included only as a general reference tool for each Policy. They may not be all-inclusive.
This medical policy was developed through consideration of peer-reviewed medical literature generally recognized by the relevant medical community, U.S. FDA approval status, nationally accepted standards of medical practice and accepted standards of medical practice in this community, and other nonaffiliated technology evaluation centers, reference to federal regulations, other plan medical policies and accredited national guidelines.
"Current Procedural Terminology © American Medical Association. All Rights Reserved"
History From 2026 Forward
| 11/01/2026 | New Policy |